Designed for beam to beam, beam to masonry or beam to steel
beam connections. MATERIAL: See table FINISH: Prime Paint FASTENERS: 10d and 16d Common Nails
PH series requires only top nailing into header.
Verify that dimensions of wood members are adequate to transfer tabulated
factored loads.
All fasteners must be installed to obtain tabulated factored resistance.
Hangers may be welded to steel headers with 11/2" long fillet welds
(weld size equal to thickness of the top flange).
For beam to masonry connection, two 16d double-headed nails must be
installed through the top flange and embeded in the grouted wall. Two
holes allow free flow of concrete.